Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730373

RESUMO

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Membro Posterior , Animais , Cavalos/fisiologia , Fenômenos Biomecânicos , Fraturas do Fêmur/veterinária , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/veterinária , Fixação Interna de Fraturas/métodos , Membro Posterior/cirurgia , Análise de Elementos Finitos , Fêmur/cirurgia , Modelos Biológicos , Suporte de Carga , Fixação Intramedular de Fraturas/veterinária , Fixação Intramedular de Fraturas/instrumentação
2.
Polymers (Basel) ; 15(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37896300

RESUMO

Preserving celluloid artifacts is challenging for museums, as this plastic is highly prone to degradation. Frozen, cold, and cool storage solutions are typically recommended for inhibiting the chemical degradation of celluloid. However, they are rarely implemented for three-dimensional celluloid (3D-CN) objects because low temperatures might cause irreversible effects (e.g., microcracking). This work presents the effects of four different storage temperatures (+23 °C, +13 °C, +9 °C, -15 °C) on the preservation of artificially aged 3D-CN mock-ups, aiming at understanding their effectiveness by measuring molecular weight distribution, camphor, and nitrogen contents after storage. Gel permeation chromatography (GPC) results showed that the least loss of camphor content and fewer polymer chain scissions happened at -15 °C, hinting that this temperature was the best for preservation. However, the heterogeneous nature of celluloid alteration, i.e., the development of degradation gradients in thicker 3D-CN objects (>0.5 mm), made it necessary to apply a novel sampling technique, which selectively considers several depths for analyses from the surface to the core (depth profiling). This depth profiling made monitoring the degradation evolution dependent on the storage conditions in the thicker mock-ups possible. This approach was also used for the first time to quantify the polymer chain scission, camphor loss, and denitration of historical artifacts, indicating a dramatic difference in the degradation stage between surface and core. The effectiveness of frozen storage on the chemical stability of 3D-CN after seven months could support museums to consider reducing the storage temperatures to preserve precious artifacts.

3.
Sci Rep ; 13(1): 2065, 2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36739445

RESUMO

Obelisks presented an important element in the architecture of ancient Egypt. This research is concerned with the re-erection of an obelisk that belongs to the famous Pharoah Ramses II. It was found broken and was transported to the Grand Egyptian Museum for restoration and display. An observation of Ramses II Cartouche at the bottom side of the obelisk base inspired the authorities to provide an innovative architectural design to display the obelisk elevated. The supporting structure was designed to allow the visitors to walk underneath the obelisk and observe Ramses II's signature. The idea of elevating the obelisk presented several challenges including evaluating the obelisk's current condition, restoration and fixation methodology, structural stability, and uncertainties of material characteristics, amongst others. To control the obelisk deformations under lateral loading, state-of-the-art base isolators were introduced. For the task to be achieved, a multidisciplinary team including historians, conservators, archaeologists, architects, and engineers with different specialties was appointed. The team performed the task successfully and currently, the obelisk stands at the entrance piazza of the Grand Egyptian Museum representing the world's first elevated obelisk.

4.
Materials (Basel) ; 14(22)2021 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-34832405

RESUMO

Carbon fiber reinforcement used in concrete has become a remarkable alternative to steel fibers. Admixing short fibers to fresh concrete and processing the material with a 3D printer leads to an orientation of fibers and a material with high uniaxial strength properties, which offers an economic use of fibers. To investigate its mechanical behavior, the material is subjected to flexural and tensional tests, combining several measuring techniques. Numerical analysis complements this research. Computed tomography is used with several post-processing algorithms for separating matrix and fibers. This helps to validate fiber alignment and serves as input data for numerical analysis with representative volume elements concatenating real fiber position and orientation with the three-dimensional stress tensor. Flexural and uniaxial tensional tests are performed combining multiple measuring techniques. Next to conventional displacement and strain measuring methods, sound emission analysis, in terms of quantitative event analysis and amplitude appraisal, and also high-resolution digital image correlation accompany the tests. Due to the electrical conductibility of carbon fibers, the material's resistivity could be measured during testing. All sensors detect the material's degradation behavior comparably, showing a strain-hardening effect, which results from multiple, yet locally restricted and distributed, microcracks arising in combination with plastic deformation.

5.
PLoS One ; 16(6): e0253002, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34101755

RESUMO

In this study, topology optimized, patient specific osteosynthesis plates (TOPOS-implants) are evaluated for the mandibular reconstruction using fibula segments. These shape optimized implants are compared to a standard treatment with miniplates (thickness: 1.0 mm, titanium grade 4) in biomechanical testing using human cadaveric specimen. Mandible and fibula of 21 body donors were used. Geometrical models were created based on automated segmentation of CT-scans of all specimens. All reconstructions, including cutting guides for osteotomy as well as TOPOS-implants, were planned using a custom-made software tool. The TOPOS-implants were produced by electron beam melting (thickness: 1.0 mm, titanium grade 5). The fibula-reconstructed mandibles were tested in static and dynamic testing in a multi-axial test system, which can adapt to the donor anatomy and apply side-specific loads. Static testing was used to confirm mechanical similarity between the reconstruction groups. Force-controlled dynamic testing was performed with a sinusoidal loading between 60 and 240 N (reconstructed side: 30% reduction to consider resected muscles) at 5 Hz for up to 5 · 105 cycles. There was a significant difference between the groups for dynamic testing: All TOPOS-implants stayed intact during all cycles, while miniplate failure occurred after 26.4% of the planned loading (1.32 · 105 ± 1.46 · 105 cycles). Bone fracture occurred in both groups (miniplates: n = 3, TOPOS-implants: n = 2). A correlation between bone failure and cortical bone thickness in mandible angle as well as the number of bicortical screws used was demonstrated. For both groups no screw failure was detected. In conclusion, the topology optimized, patient specific implants showed superior fatigue properties compared to miniplates in mandibular reconstruction. Additionally, the patient specific shape comes with intrinsic guiding properties to support the reconstruction process during surgery. This demonstrates that the combination of additive manufacturing and topology optimization can be beneficial for future maxillofacial surgery.


Assuntos
Placas Ósseas/normas , Desenho de Equipamento/normas , Fraturas Mandibulares/cirurgia , Reconstrução Mandibular/normas , Estresse Mecânico , Idoso , Fenômenos Biomecânicos , Parafusos Ósseos , Feminino , Humanos , Masculino , Teste de Materiais
6.
Ultrasonics ; 109: 106261, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32992114

RESUMO

Local ultrasonic resonance spectroscopy (LURS) is a new approach to material inspection, where the specimen is locally excited by a short mechanical impulse while its local mechanical response is recorded at a position nearby. The local material and geometrical properties can be extracted from the frequency spectrum of the response and visualized by performing a scan over the inspected area. In our experiment, the plate thickness and the reliefs of both plate surfaces (plate curvature) were obtained from thickness resonance and time of arrival analysis without physical contact to the specimen. Ultrasound was generated on the specimen surface by a laser pulse. Local mechanical response of a carbon fiber-reinforced polymer plate with a thickness ranging from 0.6 mm to 4.3 mm was recorded with a broadband optical microphone in through-transmission setup. The precision of this arrangement greatly exceeded the precision of conventional methods limited by the ultrasound wavelength. For thicknesses in the range around 1 mm, standard deviations of up to several µm were achieved. An influence of the through-plate ultrasound velocity on the measured relief of the plate surface nearest to the optical microphone was eliminated by a joint evaluation of thickness resonance and time of arrival. Furthermore, we demonstrated that internal delaminations have an influence on the spectrum of the local mechanical response and can therefore be detected by LURS.

7.
Clin Biomech (Bristol, Avon) ; 67: 1-7, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31054436

RESUMO

BACKGROUND: Clinical cartilage repair strategies can be tested using the sheep model as suggest by the European Medicines Agency. To characterize variation within the joint a full biomechanical mapping is necessary. The aim of this study is to establish a loading model, to map regional differences within the knee and determine reference areas for area specific replacement techniques. METHODS: A porous indenter was selected to evaluate 22 defined test locations (femoral condyles, tibia plateau, patella, femoral groove) on ovine knees (n = 7). A high-dynamic force-controlled micro creep and creep-recovery indentation test system applied five loading (0.11 MPa) and unloading (5.6 kPa) cycles for 60 s each and recorded creep-recovery. Needle indentation was used to measure cartilage thickness and calculate total strain. FINDINGS: Steady state behaviour was observed from the third cycle and further evaluated. Little variation of stiffness in N/mm was found within the patella (4.3SD0.5) and femoral groove (8.1SD0.7) compared to larger variations in the femur (7.9SD2.0) and tibia (7.5SD3.2). Creep indentation showed values of 14.5%(SD2.7%) for the patella and 17.4%(SD3%) for the femoral grove opposed to 13.4%(SD4.3%) for the femoral condyles and 21.8%(SD6.6%) for the tibia plateau. Similar trends were observed analysing creep-recovery. Values were normalized to cartilage thickness which ranged between 0.36 mm and 1.14 mm. INTERPRETATION: Our setup allows a reliable evaluation of zonal differences. Homogenous biomechanical behaviour is found within the patella and femoral groove whereas significant biomechanical variation within the femoral condyles and tibia plateau indicates the need for site-specific cartilage repair products.


Assuntos
Articulação do Joelho/fisiologia , Suporte de Carga/fisiologia , Animais , Fenômenos Biomecânicos , Cartilagem Articular/fisiologia , Humanos , Ovinos
8.
J Acoust Soc Am ; 142(1): EL89, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28764453

RESUMO

Classical elastic wave features like pulse velocity and attenuation have been used for decades for concrete condition characterization. Relatively recently the effect of frequency has been studied showing no doubt over the dispersive behavior of the material. Despite the experimental evidence, there is no unified theory to model the material and explain this phase velocity change at frequencies below 200 kHz. Herein, the Mindlin's strain gradient elastic theory including the additional micro-stiffness and micro-inertia parameters is considered as an alternative of multiple scattering theory. Experimental results are produced from material with dictated microstructure using a specific diameter of glass beads in cement paste. Results show that Mindlin's theory provides conclusions on the microstructure of the material and is suitable for describing the observed dispersion in different length scales (from millimeters in the case of mortar to several centimeters in the case of concrete).

9.
Ultrasonics ; 65: 96-104, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26518525

RESUMO

The time reverse modeling (TRM) is applied for signal-based acoustic emission (AE) analysis of reinforced concrete (RC) specimens. TRM uses signals obtained from physical experiments as input. The signals are re-emitted numerically into a structure in a time-reversed manner, where the wavefronts interfere and appear as dominant concentrations of energy at the origin of the AE. The experimental and numerical results presented for selected AE signals confirm that TRM is capable of localizing AE activity in RC caused by concrete cracking. The accuracy of the TRM results is corroborated by three-dimensional crack distributions obtained from X-ray computed tomography images.

10.
Sensors (Basel) ; 15(7): 14932-45, 2015 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-26121610

RESUMO

Impact-Echo (IE) is a nondestructive testing technique for plate like concrete structures. We propose a new sensor concept for air-coupled IE measurements. By using an array of MEMS (micro-electro-mechanical system) microphones, instead of a single receiver, several operational advantages compared to conventional sensing strategies in IE are achieved. The MEMS microphone array sensor is cost effective, less sensitive to undesired effects like acoustic noise and has an optimized sensitivity for signals that need to be extracted for IE data interpretation. The proposed sensing strategy is justified with findings from numerical simulations, showing that the IE resonance in plate like structures causes coherent surface displacements on the specimen under test in an area around the impact location. Therefore, by placing several MEMS microphones on a sensor array board, the IE resonance is easier to be identified in the recorded spectra than with single point microphones or contact type transducers. A comparative measurement between the array sensor, a conventional accelerometer and a measurement microphone clearly shows the suitability of MEMS type microphones and the advantages of using these microphones in an array arrangement for IE. The MEMS microphone array will make air-coupled IE measurements faster and more reliable.

11.
Ultrasonics ; 43(7): 538-46, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15950028

RESUMO

Determining the onset of transient signals like seismograms, acoustic emissions or ultrasound signals is very time consuming if the onset is picked manually. Therefore, different approaches exist, especially in seismology. The concepts of the most popular approaches are summarized. An own approach adapted to ultrasound signals and acoustic emissions, based on the Akaike Information Criterion (AIC), is presented. The AIC-picker is compared to an automatic onset detection algorithm based on the Hinkley criterion and also adapted to acoustic emissions. Manual picks performed by an analyst are used as reference values. Both automatic onset detection algorithms are applied to ultrasound signals which are used to monitor the setting and hardening of concrete. They are also applied to acoustic emissions recorded during a pull-out test. The AIC-picker produces sufficient reliable results for ultrasound signals where the deviation from the manual picks varies between 2% and 4%. Concerning acoustic emissions, only 10% of the events result in a mislocation vector greater than 5mm. It can be shown that our AIC-picker is a reliable tool for automatic onset detection for ultrasound signals and acoustic emissions of varying signal to noise ratio.

12.
Phys Rev Lett ; 89(20): 205501, 2002 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-12443484

RESUMO

The evolution of effective force chains percolating through a compressed granular system is investigated. We compressed an ensemble of spherical particles monitoring the macroscopic constitutive behavior and the acoustic signals emitted by microscopic rearrangements of particles. We applied the continuous damage model of fiber bundles to describe the evolution of the array of force chains. The model provides a nonlinear constitutive behavior in good quantitative agreement with the experimental results. The amplitude distribution of acoustic signals was found experimentally to follow a power law of an exponent delta=1.15+/-0.05, which is in good agreement with the analytic solution of the model.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...